How To Light A Whirlpool Water Heater

Help

Back It is recommended that you read the printed instructions that came with your water heater in addition to the material on this web site. Read and observe any warning labels on the water heater, as well as the safety recommendations in the printed owner’s handbook, to limit the danger of property damage, serious injury, or death.

Step1:Tools and Supplies

The pilot light should be lit if the Status Light is not blinking. If this does not work, follow the directions on the water heater’s label.

  • If the Status Light is not blinking, try lighting the pilot using the directions on the water heater’s label
  • If that doesn’t work, try another water heater. Double-check to see that the gas supply valve is switched on. When lighting the pilot, make sure that the knob on the gas control valve is fully pushed in to prevent the pilot from igniting. Maintaining the knob’s position while continuously pressing the spark igniter button is recommended. Continue to keep the knob firmly in place while pressing the igniter button repeatedly for 90 seconds. Air is present in the gas pipe of newly installed water heaters. When it comes to lighting the pilot, it may take numerous attempts

Step3:Remove the outer door

The pilot light should be lit if the Status Ignite is not flashing; if this does not work, follow the directions on the water heater’s label to light the pilot. Double-check to see that the gas supply valve is switched on, and As the pilot is being lit, make sure the knob on the gas control valve is fully pushed in to ensure proper operation. While continually pressing the spark igniter button, maintain your grip on the knob. Hold the knob in place and continually press the igniter button for 90 seconds.

To ignite the pilot, it may take many attempts.

  • If the Status Light continues to be inactive, you will need to try to visually examine the pilot light by peering through the sight glass while lighting the pilot
  • If this is unsuccessful, you will need to replace the Status Light. Remove the outer door from the frame

Step4:Look Through the Site Glass

  • You’ll need to try to visually examine the pilot light by peering through the sight glass while lighting the pilot
  • If that doesn’t work, you’ll need to replace the Status Light with another one. The outside door should be removed.

Step5:Pilot Light

It will be a little blue flame that will rise to the left and then die away.

  • An upward and to the left-facing little blue flame will serve as the pilot. It might be difficult to observe the pilot. Reduce the brightness of the lights in the room in order to better view the pilot

Help

  • Product Support
  • Locate a Service Provider
  • Check the Status of Your Warranty
  • Contact Us

Back This is a continuation of the stages taken before. If you started from this point, please review the preceding steps to make sure you’ve taken all necessary safety precautions. It is recommended that you read the printed instructions that came with your water heater in addition to the material on this web site. Read and observe any warning labels on the water heater, as well as the safety recommendations in the printed owner’s handbook, to limit the danger of property damage, serious injury, or death.

Step1:Have Spark But Pilot Will Not Light

if you can see a blue spark but the pilot does not ignite, it is likely that the pilot is not getting enough gas.

  • If you can see the blue spark but the pilot does not ignite, this indicates that the pilot is not getting enough gas.

Whirlpool water heater: will not light up

Using a thermocouple, which generates a modest electrical voltage (30 millivolts), a small electromagnet in the gas valve is able to maintain the pilot valve open after the red pilot button has been manually depressed for 30-60 seconds after the plot light has been turned on. Similarly to how a large magnetic attracts metal in a scrapyard when it is electrically powered, the electromagnet maintains the pilot valve open when it is energized. Due to the fact that the pilot valve is in series with the main gas valve, if the pilot valve is closed, the main valve will not be able to flow gas to the burner assembly, which is necessary for safety reasons.

However, this is not the case in reality; rather, it produces the opposite effect.

If the entire end of the thermocouple is baked, no temperature differential across the thermocouple is experienced, and thus no electrical power is generated; however, if baking the entire end results in the least amount of electrical power being generated, this is not true.

The threads on a water heater gas valve are typically rusted, and if the water heater is very old, the time before it begins to leak may not be far away.

In my experience, if the gas valve is bad on a water heater that is 5-10 years old, it is best and most convenient to replace the water heater instead of the gas valve.

Whirlpool Water Heater Pilot Not Lighting

Greetings, gentlemen. I’ve lived at my current residence for nearly a year. Our water heater has been making popping and cracking noises when it heats up ever since we moved into the house. The water heater has been in place for approximately 2.5 years. Following considerable investigation, we discovered that there were large calcium deposits on the bottom. We went ahead and cleaned it up as best we could, but the quantity of silt that had accumulated was remarkable, especially considering that it was only a few months old.

  • The knocking decreased at first, but returned to its previous levels a month or two later, according to the report.
  • We recently replaced the valve, but it continues to leak when the temperature rises.
  • Thanks in advance.
  • Water analysis revealed that it was not exceptionally hard, indicating that this was not the problem.
  • However, we are leaning toward replacing it rather than attempting to determine what caused it in the first place.
  • See the photos attached, which show the pressure relief valve, which is located at the top of the tank within the heater.
See also:  How Big Of A Hot Water Heater

How do you light a Whirlpool water heater with electronic pilot?

Preparing for the Pilot’s Arrival

  1. If the StatusLight is not blinking, try lighting the pilot following the directions on the water heater’s label
  2. If that does not work, try another method. Double-check to see that the gas supply valve is switched on. If the pilot isn’t lighting properly, check to be that the knob on the gas control valve is fully pushed in. Continue to keep the knob firmly in place while pressing the igniter button repeatedly for 90 seconds.

How to Turn on the Pilot Light on a Water Heater

  1. Open the door or cover that provides access to the pilot light
  2. Locate the burner within the container using a flashlight or a headlamp. Turn the gas knob to the “Pilot” position and press and hold it there. Maintain control of the gas pedal while igniting the pilot
  3. When the flame begins to ignite, keep the gas knob or button down for a full minute.

Furthermore, how can I determine whether the pilot light on my water heater has gone out? Identifiable by the slight upturn at the end, the pilotgas line is a tiny metal tube that runs below the burner assembly and is distinguished by its location below the burner assembly. It will be obvious whether the pilot is ignited by the faint blue flame that will be seen at the end. If you do not see a little blue flame burning, this indicates that the pilot light is not working. Is it true that electric water heaters have pilot lights in this case?

  • If you see a pilot light, this indicates that you have a gas water heater.
  • On a manual water heater, how do you turn it on?
  • Turn the knob on the gas regulator valve to “Pilot,” press down on it, and keep it pressed down.
  • Some water heater types require you to push and hold down a separate red button in order to initiate the flow of pilot burner gas.

How do you manually light a Whirlpool water heater?

Check to see that the gas supply valve is switched to the on position. If the pilot isn’t lighting properly, check that the knob on the gas control valve is fully pushed in. Keep the knob firmly pressed in while continuously pressing the spark igniter button on the ignition switch. Keep the knob firmly in place and continually press the igniter button for 90 seconds. Using the flashlight, shine a light on the pilot burner. Turn the knob on the gas regulator valve to “Pilot,” press down on it, and keep it pressed down.

  1. Some water heater types require you to push and hold down a separate red button in order to initiate the flow of pilot burner gas.
  2. The pilot lightflame heats a device known as a thermocouple, which measures temperature.
  3. A pilot light failure results in the shutoff of the gas supply, with no danger of gas collecting as a result of the pilot light being out.
  4. Identifiable by the slight upturn at the end, the pilotgas line is a tiny metal tube that runs below the burner assembly and is distinguished by its location below the burner assembly.

It will be obvious whether the pilot is ignited by the faint blue flame that will be seen at the end. If you do not see a little blue flame burning, this indicates that the pilot light is not working. What is the proper way to reset my water heater? The Reset Button is pressed in Part 2.

  1. Locate the red reset button on the control panel. In the middle of the control panel, there should be a red button
  2. Press the button firmly to activate it. The reset button can become stuck from time to time, especially if you haven’t reset the heater in a long time
  3. However, this is rare. Wait for the sound of the button clicking.

Why Your Water Heater’s Pilot Light Keeps Going Out & How to Fix It

The date is May 13, 2021. When the pilot light flame on your gas water heater goes out, it is an annoying and frustrating situation to have to deal with. When your water heater’s pilot light fails to stay lit, you’re left without hot water, which makes even the most basic of tasks such as taking a shower a chore. Naturally, you question, “How did this happen? What happened?” Is there anything you can recommend to help you get things going again? What should I do to have it repaired? “May you tell me about the costs I can expect?” Fortunately, if your water heater pilot light goes out, you should be aware that this is a frequent problem that many homeowners have and that the time and effort required to repair it is low.

Why does the pilot light on my water heater keep going out?

Because of problems with the heater’s thermocouple or owing to access to combustible air, your water heater’s pilot light continues going out repeatedly.

Thermocouple Issues

When your pilot light is on, your thermocouple detects the presence of the flame. The thermocouple’s tip is positioned above the pilot flame, providing a voltage that maintains the gas valve open in the process. A thermocouple will shut down the gas supply to your water heater if it detects that the pilot light on your water heater is not lighting up properly. When thermocouples are exposed to moisture or dust for an extended period of time, they might malfunction, gather dust, or get bent away from the pilot light’s flame.

Lack of Combustible Air

Another reason why your gas water heaterpilot light won’t remain lighted might be that there isn’t enough combustible air in the room where it is located. To keep the pilot light on in your water heater, you’ll need to blow air into it. Otherwise, the flame will be extinguished. Take precautionary measures to ensure that the water heater is not surrounded by material, such as litter or lint, which might increase the quantity of combustible air present. Maintain as much cleanliness as possible in the surrounding region.

See also:  How To Test Electric Water Heater Thermostat

What do I do if my water heater pilot light keeps going out?

Try to rekindle the spark on your own first, if at all possible. Take the following general steps:

  1. Locate the gas shut-off knob and turn it all the way to the “Off” position. The gas flow is halted as a result of this. Allow for a few minutes for the gas to dissipate before continuing. To get access to the burner, remove the access panel. To begin the flow of gas, turn the knob to the “Pilot” position. You’ll want to press and hold the knob down for a few seconds. While still holding the gas knob, ignite the pilot with a long lighter while still holding the gas knob. To ignite your gas water heater, use the button on the side of the tank that says “ignite.” As soon as the flames have been extinguished, turn the gas knob to the “On” position and wait for the main burner to come on.

If you are unable to relight the pilot or if your pilot light keeps going out, it is possible that you have another problem, such as a faulty thermocouple, to consider. Please refer to the owner’s handbook for your water heater equipment for further information.

Can I replace a thermocouple myself?

Yes. In the event that you are handy with tools, you may be able to change the thermocouple yourself. It is easier to accomplish this by turning off the gas valve and removing the entire burner and thermocouple assembly.

In the case of minor repairs, it is preferable and safer to hire someone who is knowledgeable in the field of repair. A specialist may also evaluate your water heater for other faults and provide advise or ideas on how to deal with any existing or future difficulties that may arise.

Call BGE HOME

Please contact BGE HOME at (410) 918-5600 if your water heater pilot light will not light or continues going out. You may also contact us online. Our licensed specialists are available 24 hours a day, seven days a week to come out and inspect your water heater and make recommendations on how to get it running safely and effectively again. This item was posted on Thursday, May 13th, 2021 at 4:09 pm and is filed under Uncategorized. Commenting and pinging are temporarily closed for this post.

Operating Your Water Heater; Lighting Instructions – Whirlpool 12307 Installation Instructions And Use And Care Manual [Page 17]

Before attempting to ignite or relight the pilot, be sure you have properly read and comprehended the instructions. Check to ensure that theviewport is not missing or damaged in any way. (See Illustration 23.) Before lighting the pilot, check to see that the tank has been entirely filled with water. Check the data plate located near the gas controlvalve/thermostat to ensure that the proper gas is being used. It is not recommended to use this waterheater with any other gas than the one specified on the dataplate.

  • A piezoelectric igniter is used to light the pilot in this appliance.
  • This appliance has a pilot light.
  • PREVIOUS TO LIGHTING, SCENT FOR GAS ALL OVER THE AREA AROUND THE APPLIANCE Keep an eye out for gas smells near the ground since some gases are heavier than air and will settle on the ground.
  • STOP RIGHT NOW!
  • 2.
  • 3.
  • 4.

5.

If you smell gas after that, STOP!

If you do not detect any gas, go to the next step.

Rotate the gas control knob counterclockwise until it reads “PILOT.” Step 1: Rotate the temperature dial counterclockwise to the lowest position.

If you do not follow these directions completely, a fire or explosion may occur, resulting in property damage as well as physical harm or death.

Do not touch any electrical switches or make any phone calls in your building until further notice.

Follow the instructions provided by your gas supplier.

INSTRUCTIONS FOR LIGHTING THE RESET130° FBUTTONBARGASCONTROLKNOBTDIALSTOPINDEXBARSS130° FBARTO TO TURN OFF THE GAS TO THE APPLIANCEC Pushing in or turning the gas control knob will require only your hand.

It is not recommended that you attempt to fix the knob yourself.

The use of force or the effort to fix anything may result in a fire or an explosion.

Call a trained service expert to come assess the equipment as soon as possible.

WARNING: THIS APPLIANCE SHOULD NOT BE USED IF THERE HAS BEEN ANIGNITION OF VAPORS.

Water heaters that have been exposed to combustible vapors will develop discoloration on the air intake grid, necessitating the removal and replacement of the complete water heater.

Push the reset button all the way in, then immediately press theigniter button until you hear a loud click.

Through the view port, you can keep an eye on the pilot.

If the pilot does not ignite on the first attempt, try again immediately.

120° F4 – 7 degrees Celsius Continue to hold the button forBARabout (1) minute after the pilot is ignited to ensure that the button is not accidentally released.

The pilot should be lighted at all times.

CAUTIONIMPORTANT: The reset button (as seen in the graphic at step 3) should not be used if the DO NOT PRYON DIALDAMAGEWILL NOT come up when released.

BRING THE GAS BACK TO THE LINE VALE OR THE TANK Contact your service technician or natural gas supplier for assistance.

Turn the gas control knob counterclockwise until it reads “ON.” PRECAUTIONS: DO NOT PRY9.

RESULT 10.

Turn the gas control knob in the clockwise direction.

WARNINGThere is a risk of explosion. If the glass in the viewport is missing or broken, it should be replaced. Death, explosion, and fire are all possible consequences of failing to do so. PRECAUTIONS:DO NOT PRYON DIALDAMAGEWILL RESULT IN THE “OFF”17

Amazon.com : whirlpool water heater parts

Only 2 units left in stock – purchase soon. Ships to the Netherlands The Netherlands is served by this item. There are just 5 left in stock – purchase soon. Sketch was used to create this design. Sponsored Get it as soon as possible. Tuesday, March 8 Shipping is $81.23 USD. Ships to NetherlandsThere are only 6 of these items left in stock – purchase soon. Ships to NetherlandsThere are only 15 of these items left in stock So purchase soon. Ships to the Netherlands are available. Only 18 of these items are left in stock – purchase soon.

  1. With the coupon, you may save 5 percent.
  2. Ships to NetherlandsThere are only 20 of these items left in stock So purchase soon.
  3. With the coupon, you may save 5 percent.
  4. Only 9 units left in stock – purchase soon.
  5. Only 2 units left in stock – purchase soon.
  6. Ships to the Netherlands Ships to NetherlandsThere are only 20 of these items left in stock So purchase soon.
  7. Ships to the Netherlands With the SubscribeSave discount, the price drops to $9.49.
  8. With the coupon, you may save 5 percent.
See also:  Why Does Pilot Light Go Out On Water Heater

How to Fix a Water Heater Pilot Light

Time Approximately one hour or less Complexity Cost for a beginner is less than $20.

Introduction

If your hot water heater suddenly stops operating, it’s likely that a faulty thermocouple has caused the gas to the pilot light to be turned off. Replacement is a simple do-it-yourself project.

Tools Required

A damaged thermocouple may have caused the gas to the pilot light to be turned off in your hot water heater if it abruptly stopped operating. An easy do-it-yourself repair is replacement.

What is a Thermocouple?

  • In order for gas to flow to the burner, a thermocouple must be used to detect the heat of the pilot. A faulty thermocouple will prevent gas from reaching both the pilot and the burner, resulting in the pilot light failing to stay lit.

Project step-by-step (6)

  • Shut off the gas line by closing the cutoff valve. As seen in this photo, turn the valve a quarter turn so that the handle is at a right angle to the pipe.

Unscrew the Nuts

  • Make sure you turn off the gas cutoff valve. Check that you have turned the valve one-quarter turn so that the handle is at a straight angle to the pipe, as shown in the photo

Sign Up For Our Newsletter

Complete your do-it-yourself tasks like an expert! Become a subscriber to our newsletter! Do It Right the First Time, and Do It Yourself! Step number three.

Remove the Assembly

  • Remove the water heater pilot light burner component from the water heater. Remove the old thermocouple by unscrewing or pulling it out. Purchase a new one that is the same size and length as the previous one

Install the New Thermocouple

  • Install the new thermocouple in the same manner as the previous one
  • Replace the burner assembly by sliding it back in. Reattach the three wires to the control valve where they were disconnected.

Reattach the Lines to the Gas Valve

  • The three lines must be reconnected to the gas valve by threading the nuts into position with your fingers and hand-tightening them
  • A quarter- to half-turn of the wrench tightens them up.
  • Pro tip: Because the metals are delicate, avoid overtightening them.

Test for Gas Leaks

  • Keep in mind that in order to test for leaks, the pilot light must be lighted and the burner turned on so that gas flows through the big tube.
  • Replenish the water supply by opening the shutdown valve and lighting the pilot light. Turn the control valve to the “on” position. Use a 50/50 mixture of dish soap and water to check the screw joints for air bubbles, which indicate a leak, while the gas burner is turned on.
  • Keep in mind that when the water heater pilot light is re-ignited, the flame should wrap around the thermocouple bulb.

CAUTION!

During this procedure, you should not be able to detect the scent of gas (except for a slight whiff when you remove the gas lines). If you find yourself in this situation, exit the house immediately and contact your gas provider.

WhenNotto Replace the Thermocouple

Some gas water heaters have a burner chamber that is “closed,” making it impossible to reach the burner. It is recommended that you contact a professional to repair this sort of heater. In addition, some gas water heaters are not equipped with pilot lights. Allow the professionals to take care of this as well.

Whirlpool Residential Gas Water Heater with the Flame Lock Safety System – Manual (Page 28)

CODE FOR THE STATUS LIGHT TROUBLESHOOTING CHART LED STATUS PROBLEM 28STATUS LIGHT CODE IMPROVEMENTAL ACTION ZERO FLASHES (LED NOT LIT) The pilot light is not turned on. There is insufficient electricity (in millivolts) to keep it lighted. Observe the illumination instructions on the front of the water heater and make a note of any diagnostic codes that are shown there. See the Diagnostic Status Light Codes section for further information. 1 FLASH OF ILLUMINATION (EVERY 3 SECONDS) Normal business operations.

Insufficient electricity (millivolts) is supplied to the gas control valve/thermostat in two flashes.

Double-check all of the wire connections.

2.

See “Replacing the Pilot/Thermopile Assembly” for further information.

The gas control valve/thermostat should be replaced.

5 FLASHESSensors have failed.

Refer to “Removing and Replacing the Gas Control Valve/Thermostat” for further information.

The gas control valve/thermostat should be replaced.

a total of 8 FLASHES This condition will only emerge if the gas control/temperature knob has been turned off and the thermopile has continued to generate electric power while the knob has been turned off.

In addition, if the gas control/temperature knob has been turned off and the pilot continues to function because the pilot valve is locked in the open position, this circumstance can arise.

Please wait a moment.

See if there is a pilot flame visible through the sight glass.

Turn off the main gas supply at the breaker.

Refer to “Removing and Replacing the Gas Control Valve/Thermostat” for further instructions.

If the pilot flame is not visible while the gas control valve/thermostat knob is set to the OFF position, the pilot should be replaced.

If this issue recurs, the gas control valve/thermostat should be replaced. Follow the steps in “Removing and Replacing the GasControl Valve/Thermostat” to complete the task.

Leave a Reply

Your email address will not be published.