What Size Wire For Water Heater

What Gauge of Wire is Used to Wire a 220-Volt Hot Water Heater?

In order to properly wire a hot water heater, it is necessary to adhere to the National Electrical Code, which defines the wire gauge size and circuit breaker size dependent on how much current the hot water heater draws.

Voltage Requirements

The majority of electric hot water heaters operate on alternating current (AC) voltages ranging from 220 to 250 volts. The hot water heaters require a double circuit breaker that is rated for the amperage draw of the hot water heaters in order to operate at this voltage in a residence.

Power Requirements

AC voltage ranges from 220 to 250 volts for most electric hot water heaters. The hot water heaters require a double circuit breaker with an amperage rating equal to or greater than the voltage in the residence.

Common Current and Wire Gauge Sizes

Installing a hot water heater requires the use of wire that is large enough to handle the current demand of the heater. Typical hot water heater sizes are as follows: a 20-amp hot water heater requires 12-gauge wire, a 25-amp hot water heater requires 10-gauge wire, and a 30- to 40-amp hot water heater requires 8-gauge wire. Because some big heaters can draw as much as 50 amps, 6-gauge wire is required.

What Size Wire for a 40-Gallon Electric Water Heater? [Explained]

It is possible that we will receive commissions for purchases made through the links in this post. It is critical to determine the optimal size of wires for a 40-gallon electric water heater before installing them. Short circuits can occur when cables are not properly matched. You don’t want to be in that situation, do you? What size wire should be used for a 40-gallon electric water heater is the subject at hand. The wire gauge required for a typical 40-gallon electric water heater is 12 gauge.

The current will exceed its capacity, and the wire will begin to melt.

Discover what factors we should take into consideration while selecting a heater wire.

Why The Sizes of Wires Vary in Different Water Heaters?

Water heaters are available in a variety of sizes and capacities. Wire sizes vary depending on the size of gallons used in each application. The recommended wire size for a 40-gallon electric water heater, for example, is 12 gauge wire. Electric water heaters with a capacity of 50 gallons require wire with a gauge of 6. The gallon size is proportional to the size of the wire. It is also possible that the wiring will differ depending on whether the water heater is mounted vertically or horizontally.

For example, the recommended wire size for a 20-amp hot water heater is 12-gauge wire.

How to Calculate A 40 Gallon Water Heaters Wire Size

When it comes to a 40-gallon heater, you can’t just pick any wire size anymore. To begin, you must gather data in order to be able to quantify it. As an example:

  • The size of the wire used in a 40-gallon heater may no longer be selected at random. Before you can measure something, you must first get some data. Take, for instance,

For a 40-gallon heater, you can’t just pick any wire size anymore. To begin, you must gather data in order to be able to measure it. As an example, consider the following: So now that you have your wire, let’s have a look at why it’s so vital to have the proper length of wire.

Why Matching The Wire Gauge Is Important For An Electric Heater

If you’re replacing the wires for your heater, you should be aware of the importance of matching the wires correctly. It lessens the likelihood of the wire being heated. Short circuits, on the other hand, will result if you utilize wire that is not matched. How? Suppose you’re utilizing a 40-gallon water heater on a 30-amp circuit with 6-gauge wire. Here’s why: A heater operating at 220 volts generates more current than the circuits can handle. It begins to melt the items in its immediate vicinity, just as when your shower cable warms up!

One miscalculation might possibly result in the death of someone.

Things to Keep in Mind While Replacing Wires of An Electric Heater

In order to understand why it is so important to match the wires for your heater while changing them, consider the following: There is less likelihood of the wire being heated. Short circuits, on the other hand, will occur if you utilize wire that is not matched. How? Suppose you’re running a 40-gallon water heater on a 30-amp circuit with 6-gauge cable. Here’s why: A heater operating at 220 volts generates more current than the circuits can handle. This is comparable to what happens when your shower wire becomes hot!

This is an extremely serious hazard situation.

  • The circuit wire is included, as is a double-pole breaker with a 40-amp rating. It also contains 10-2 non-metallic (NM) cables
  • The black circuit wire should be connected to the lead of the black wire in order to complete the circuit. The white circuit wire should be used to connect the lead of the red or white wire
  • The white circuit wire should be wrapped with black or red electrical tape at the breaker box. It serves to distinguish between which wire is considered to be “hot” and which is considered to be “neutral.” A 240-volt circuit allows electricity to flow via both wires (black and white). Connections should be made by connecting the circuit ground wire to the green ground screw on the water heater

a double-pole breaker of 40 amps is incorporated for circuit protection. NM cables are also included in the 10-2 category; the black circuit wire should be connected to the lead of the black wire. a white circuit wire should be used to link the lead of either the red or white wire; at the breaker box, the white circuit wire should be wrapped with either black or red electrical tape It serves to distinguish between which wire is considered to be “hot” and which wire is considered to be neutral.

Consequently, connect the circuit ground wire to the water heater’s green ground screw.

FAQs

Is it possible for me to replace my hot water heater myself? Answer: You can replace a hot water heater on your own if you have some prior knowledge in the field. However, no matter how much experience you have, you must first obtain authorization to do so. Also, before you replace them, make sure you know what to do and what not to do. Is it possible to use a 40A circuit breaker on a 10 gauge wire? Answer: It is not possible to install a 40A breaker on a 10 gauge cable. For a 40A circuit breaker, you’ll need to utilize wire that’s 8 gauge or smaller.

The answer is 4500 watts divided by the number of amps.

This is for a 240-volt electric circuit.

Bottom Line

That’s all there is to it! You can now determine the size of the wire needed for a 40-gallon electric water heater by measuring it.

If you wish to change the wires in your heater, you should follow the directions in this page. That’s all there is to it for today! I hope we’ve cleared up any ambiguity about what has to be done. Until then, keep yourself safe and sound!

Hello, my name is Melissa and I’m writing from Illinois, United States. I’ve been in the furnace operator and tender industry for a number of years now, and I’m passionate about making people’s lives more comfortable in their own residences. Melissa Hawkins’s most recent blog entries (See all of them)

Wire Size For Water Heater Based Upon Amp, Watt, Gallon

Do you have a brand-new water heater in your home? Are you considering doing the electrical work yourself? You’ll need cables that are the proper size. A fire might be started if the improper size is used.

What Size Wire Do I Need For My Hot Water Heater?

When it comes to amperage,

Amperage Wire Size
20A 12 Gauge
25A 10 Gauge
30A 8 Gauge
50A 8 Gauge
60A 6 Gauge

When it comes to wattage,

Watt Wire Size
2000W 10 Gauge
2500W 8 Gauge
3000W 6 Gauge
3500W 6 Gauge
3800W 4 Gauge
4500W 4 Gauge
4800W 3 Gauge
3KW 6 Gauge

The voltage used in this computation is 120V. in gallons per gallon

Gallon Wire Size
30 Gallon 12 Gauge
40 Gallon 12 Gauge
50 Gallon 6 Gauge
80 Gallon 6 Gauge

This calculation is based on the following information: 240VWire Size For Tankless Water Heating

Watt Wire Size
7600W 4 Gauge
9600W 3 Gauge
11500W 2 Gauge
13400W 1 Gauge

This computation is based on a 240V power supply. The thicker the wire is, the higher the amp rating of the circuit. This is the approach taken by the majority of electrical experts. Once the water heater’s amp rating surpasses 50A, they will only utilize 6-gauge wire to connect it.

How Do I Find Out What Size Wire Is Best For My Water Heater?

The amperage is required in order to compute the correct wire size. Consider the following scenario: you have a 3,000W heater that operates on 120V. Following the 80 percent rule, the amperage is calculated as (3000/120)*80 percent, which results in a total of 45 amps. According to the amperage table, 8 gauge wire is the ideal wire size for a 3000W heater. You must also take these considerations into consideration.

1). Voltage

Having the amperage on hand will allow you to determine the correct wire size. If you had a 3,000-watt heater that works on 120V, for example, you might use it. A 45-ampere circuit may be calculated using the 80 percent rule by multiplying (3000/120)*80 percent, which results in a current of 45 amps. The ideal wire size for a 3000W heater, according to the amperage table, is 8 gauge. These considerations must also be taken into consideration.

2). Wattage

This measurement indicates the amount of power consumed by the water heater. The wattage of a water heater, on the other hand, cannot be used to calculate the size of the wire to utilize. You’ll require the amperage.

3). Breaker Size

Technically speaking, you do not need to know the size of the circuit breaker in order to compute the size of the water heater wire. Once you’ve determined the voltage of your circuit and the wattage of the heater, you can calculate the amperage, which, in turn, shows the size of the wire. The size of the breaker, on the other hand, is equally significant. In the first place, adding a water heater to a circuit breaker of a lesser capacity may cause the breaker to trip repeatedly, which is inconvenient.

It is critical to consider the size of the breaker.

For example, in the previous example, once you have determined the amp rating of your water heater (25A), you must increase that value by 125 percent in order to comply with NEC standards.

When choosing a breaker, try for a size that is as near as possible to 31 amps in rating. The obvious solution is a 35A circuit breaker. Because of this, a 25A water heater requires a 35A breaker to be installed. A 35A breaker necessitates the use of an 8-gauge wire.

4). Gallons

It is not necessary to know the size of a circuit breaker to compute the size of a water heater wire, at least not technically speaking. With the voltage of your circuit and the wattage of your heater, you can calculate the amperage of your circuit, which will disclose the size of your wiring. The size of the breaker, on the other hand, is equally significant. As a starting point, when you connect a water heater to an electrical panel that is too small, the breaker will trip repeatedly, which is inconvenient and dangerous.

  1. Important considerations include the size of the breaker.
  2. Using the previous example, once you have determined the amp rating of your water heater (25A), you must multiply that amount by 125 percent in order to comply with NEC requirements.
  3. Make an effort to find an ampage that is close to 31 amps when choosing a breaker.
  4. The following diagram illustrates the requirements for a 25A water heater and its associated circuit breaker: It is necessary to use an 8-gauge cable for a 35A circuit breaker.

What Kind Of Wire Should I Use?

You’ll need shielded metallic wires to complete the job. Pay close attention to the gauge and how it relates to the distance traveled. The majority of people are aware that a greater amp rating necessitates the use of thicker wire with a smaller gauge. They are unaware that when the distance between the two points grows, the thickness of the wire should rise as well. Posts Related To This:

  • Thermoelectric Water Heater (Red, Green, Blue) Light Blinking/Flashing Symbolism
  • Does a Water Heater Require a Disconnect Switch? Explanation of the amp, height, and size

How Many Wires Does A Water Heater Need?

A water heater necessitates the use of three wires: a black wire, a white wire, and an earth wire. The white and black wires of a 10-2 ground shielded cable serve as hot conductors in this configuration. The neutral wire will be connected to the ground wire. It is the black and red wires that are the hot conductors in a 10-3 ground shielded cable with an extra conductor if the cable has a total of three conductors.

Why Does Wire Size Matter For My Hot Water Heater?

It is more probable that a wire that is too tiny (with a higher gauge number) may melt and cause a fire. This is due to the fact that the water heater will compel the wire to carry more power than it is capable of delivering. Overheating will result as a result of this. Please keep in mind that a smaller diameter corresponds to a higher resistance. Furthermore, the higher the resistance of a wire, the more heat it will emit. When it comes to gauge, the smaller the wire is, the higher the number on the gauge is.

See also:  Which Water Filter Is Best

Taking the example of wire gauge, a 6-gauge wire is thicker than a 10-gauge wire.

It is preferable to utilize larger cables than it is to use smaller wires.

The expense, on the other hand, is expected to climb. You may not be aware that bigger cables are more expensive than their thinner equivalents. It’s important to choose wire that is the proper size for the wattage of your heater in order to avoid excessive costs and perhaps disastrous fires.

Does A Hot Water Heater Have To Be Hardwired?

It is not necessary to have a hardwired system. An electric water heater necessitates the installation of a dedicated 240V circuit. You should be able to connect your heater to a 30A double pole breaker, depending on the wattage of the heater. It is not necessary to hardwire your water heater in order for it to satisfy these fundamental standards. As a result of the only thing they can see, many people believe that a water heater must be hardwired. Those who believe in the dangers of cord and plug water heaters believe that the water heater will ultimately overload one or both of the power cable and the wall outlet.

  • Nothing has to be hardwired in order for it to work. A dedicated 240V circuit is required for an electric water heater. You should be able to connect your heater to a 30A double pole breaker, depending on its wattage. For these fundamental criteria, you do not need to hardwire your water heater. The fact that a water heater is hardwired leads many individuals to believe it is the only option. Those who believe in the dangers of cable and plug water heaters believe that the water heater will ultimately overload one of the electrical cords or one of the wall outlet connections. That, however, is not the case.

Other outlets on the circuit can be blocked from being used by other individuals by placing tape over the slots on the circuit.

What Does The NEC Say About It?

1) Fixed-storage water heaters are classified as continuous loads under the National Electrical Code. It is necessary to have temperature-limiting functions in the controls. 3). According to the National Electrical Contractors Association, the circuit rating should be at least 125 percent of the heater’s amp rating. 4). The National Electrical Code (NEC) anticipates that users will utilize 10/2 conductors for heaters rated at 4500W. Check the fire and electrical codes in your area. If it specifies the wire diameters that should be used for water heaters of specific ratings, you should pay attention to it.

Can I Use 10 3 Wire For A Hot Water Heater?

You may use a 10/3 wire for this project. The red and black wires should be used as hot conductors. The ground wire will be routed to the green screw on the bottom. Remove the cap from the white wire. Your electrician will not be able to purchase 10/3 wire for your heater. However, if you have already purchased one, they will be able to make it work.

Can I Use 10-2 Wire For A Water Heater?

A 10/2 cable can be used in this situation (with a ground wire). Water heaters are often wired using this type of cable, which is the most popular type used by electricians. A 10/2 cable is composed of two conductors. It is ideal for breakers with a current of 30A.

Can You Use 12 2 Wire For A Water Heater?

There is nothing wrong with utilizing 12/2 wires in your installation. However, I recommend that you utilize 10/2 wires. Even if you have a smaller water heater with a lesser wattage, 10/2 wires allow you the flexibility to upgrade your water heater in the future if your needs change. If you decide to upgrade to a larger, more powerful unit in the future, you will not have to go through the hassle of changing all of the wiring.

wire size for 50 gallon Rheem

Over 680,000 strictly plumbing related postsWelcome to Plbg.com the PlumbingForum.com. We are the best online (strictly) PLUMBING advice, help, dyi, educational, and informational plumbing forum. Questions and discussions about toilets, sinks, faucets, drainage, venting, water heating, showers, pumps, and other exclusively PLUMBING related issues.Please refrain from asking or discussing legal questions, pricing, where to purchase a product, or any business issues, or for contractor referrals, or any other questions or issues not specifically related to plumbing.Keep all posts positive and absolutely no advertising. Our site is completely free, without ads or pop-ups. We do not sell your information. We are made possible by:
wire size for50 gallon Rheem
Author:chip (OH)would10 wire be safe for a 50 gallon rheem240 volt water heater with 3500 watt elementson 2 20 amp breakers?the romax is currently12-2 from the breaker box to the heater is around 30′ i was thinking of upgradeing to10 would that be ok on 2 20 amp breakers?thanxChip
Post Reply
Re: wire size for50 gallon Rheem
Author:Dunbar (KY)10 wire is rated for 30 amps12 wire is rated for 20 amps12/2 is more than enough for 3500 watt/3800 watt elements. When you have 4500 or 5500 watt elements you must use10 wire/30 amp circuit. No exceptions on that spec.Nothing wrong with upsizing the wire as you describe. It wouldn’t be necessity to do so with the requirements needed with the water heater you are installing. An electrician would ask why bother. But the good thing in your changing of the wire would allow for a higher wattage heater to go in without doing anything other than switching the breaker to a double 30.Not an electrician but I’ve done a great deal of this in my day.A huge misconception people “think” they can increase the breaker size without increasing the gauge of the wire. Not a good thing and a fire/electrical hazard can follow.
Post Reply
Re: wire size for50 gallon Rheem
Author:chip (OH)Ok,then i’ll leave the 20 amp breakers in theirand run a new12-2 line from the heater to the box,a few years ago they made the romax coler coded is’nt14 yellow and12 orange?ThanxChip
Post Reply
Re: wire size for50 gallon Rheem
Author:packy (MA)i like dunbar’s advice of up-sizing the wire to a10. i believe10 is orange.
Post Reply
Re: wire size for50 gallon Rheem
Author:ev607797 (NC)The Romex (NM-B cable) coloring is white jacket for14 cable, yellow for12 and orange for10.Larger sizes are usually black or gray, but there’s really no color standard for anything larger than10.The standard for water heater circuits is10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.If you are running cable anyway, just run10 and replace the breaker so it’s done right, once and for all.Unless you are installing a commercial unit, that’s all you will ever need to have in place in a residential environment.Remember that even though electric hot water heaters have two heating elements (upper and lower), they are NEVER operating at the same time.The upper thermostat functions to “ping-pong” the elements on and off.I once had a customer (when I was an electrician) demand that we provide a 50 amp circuit for an electric water heater to replace a propane one.His logic was that since there’s a potential 9,000 watt load (two elements), we must install a circuit that is prepared for it.After a few minutes of “electric water heater 101”, he understood and we saved him a bunch of money.-Ed-
Post Reply
Re: wire size for50 gallon Rheem
Author:hj (AZ)10 would be adequate for almost any residential water heater, the gallonage is immaterial. However, most heaters you will find are going to be 4,500 watts. The lower wattage ones are not usually a normally stocked one, and could be called “energy efficient”, but are really just slow heating ones.
Post Reply
Re: wire size for50 gallon Rheem
Author:chip (OH)Thanks for all the info guys!I’ll let youknow how it turned out.Chip
Post Reply
Re: wire size for50 gallon Rheem
Author:Edward429451 (CO)What would be the reasoning for upgrading the wire size to10 and not going ahead and snapping in a twin 30 breaker?You may as well expect someone to put in a 4500W element when one of the originals go bad.
Post Reply
Re: wire size for50 gallon Rheem
Author:hj (AZ)The only “good” reason would be if the heater has wires just adequate for the 3600 watt elements, in which case the 30 amp breakers would create an unsafe condition.
Post Reply
Re: wire size for50 gallon Rheem
Author:chip (OH)the way it’s geared up now is12/2 twin 20amp breakers which is adaqueate for the rheemtank i have with 3500 watt elements,if i do upgrade to10 wire than of course i would have to change the twin breakers from 20 amp to 30 amp because it could be a fire hazzard with10 on twin 20 amp breakers,now let’s say i remove the 12/2 cable and remove the twin 20 amp breakers and run a new10 wire to the box with new twin 30 amp breakers would that at all affect the elements being that they are only 3500 watt and not 4500 watt?
Post Reply
Re: wire size for50 gallon Rheem
Author:hj (AZ)There is no “fire hazard” with10 wires and a 20 amp breaker. The fire hazard comes in when you have12 wires and a 30 amp breaker. The purpose of a circuit breaker is to protect the wires, and they dictate the maximum size breaker that can be used, not the other way around. With10 wires you can use ANY breaker up to 30 amps. The anomaly ia that the heater’s internal wiring, except for those with 5500 watt elements, is12 wiring.
Post Reply
Re: wire size for50 gallon Rheem
Author:chip (OH)i misunderstood before i understand now thanx.Chip
Post Reply
Re: wire size for50 gallon Rheem
Author:rhoskins (AL)My hot water heater will require 65 feet of cable.Is10 wire adequate for a 50 gal. Rheem so far from the main breaker box?
Post Reply
Re: wire size for50 gallon Rheem
Author:eschat (FL)So are you saying that the wiring inside a 5500w tank is different than tanks with less wattage?I am planning to install a 5500w tank into a dbl 30 Amp Breaker using 10-2 wire with copper ground.Do I have it right to upgrade my wire 14-2 to the 10-2 size?Is that what I need to bring things up to code?
Post Reply
  • The use of 12/2 wires is completely acceptable. 10/2 cables, on the other hand, are what I recommend. Even if you have a smaller water heater with a lesser wattage, 10/2 wires allow you the flexibility to upgrade your water heater in the future if you so want. If you wish to upgrade to a larger, more powerful unit in the future, you will not have to go through the hassle of changing all of the wiring.
Search for plumbing parts on our sponsor’s site:


Special thanks to our sponsor:

Color code for residential wire/ how to match wire size and circuit breaker

Use only 600 volt wire.Lamp cord, extension cords are not rated 600 volt.Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional.30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire. cannot be connected to 15-20-40 amp breaker.Orange/10 gauge wire, with ground. 30 amp capacity. Safe maximum: 30 x 80% = 24 amps.Buy:10-2 gauge/ 30 amp10-3/ 30 ampSouthwire electric tools Yellow 12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. . cannot be connected to 30-40 amp breaker. 1Yellow/12 gauge wire, with ground. 20 amp capacity. Safe maximum 16 amps.Buy:12-2 gauge/ 20 amp12-3/ 20 ampNMB is house wiringUF is undergroundRolls of stranded wireHOOK UP Wires White 14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker.White/14 gauge wire,with ground. 15 amp capacity. Safe maximum 12 amps.Buy:14-2 gauge/ 15 amp14-3/ 15 ampNMB is house wiringUF is underground
50-60 amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker onlyBuy:6-2 wireSouthwire electric tools NMB is house wiringUF is underground 40-50 amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker onlyBuy:8-2 wireSouthwire electric tools NMB is house wiringUF is underground Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire.Generally. use same size as other wire in circuitBuy:12 gauge copper ground wireGround wireGreen ground wireGround pigtailsGround rods/ ground clamps at Amazon
Non metallic flexible cablesmust carry ground wire, but do not have hazard of short circuit causing injury from shock.Armored steel cablecan be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure.All conduit.metal, plastic. flexible and rigid. must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure.Buy:Non-metallic flexible conduitPower whipArmored cableSouthwire armored cable cutterPull boxes Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power. even when breaker is off.Buy:Electrician tools kitsKLEIN TOOLSTools kitsIRWIN toolsKNIPEXTelephone cable knifeLow Voltage Mounting Bracket for Telephone 600 volt 12 ga Stranded wireot THHN wire is good for conduit with multiple wires. but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk. of heat causing splayed strands.that come loose. and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring.Project wire, extension cords, thermostat, bell and automotive wire are not rated for residential or commercial wiring. Only wire maked 600 volt can be used for permanent household wiring.Buy:Southwire 600 volt stranded wireRolls of stranded wireHOOK UP Wires
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.-Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15BuyEnd cutting nippers at Amazon Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point.Buy tools:KLEIN TOOLSWire strippers at AmazonElectric Wire Stripping MachineLinesman pliersUtility knife at Amazon Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire.Buy:Analog multimeterMultimeters at AmazonKlein multimeterElectric testers at AmazonClampmeter for testing amp flow on line
Household NM-B Wires are color-coded so inspectors/ electricians can easily identify which wire is used during constructionDamp- wet locations:For direct burial underfoot, in contact with damp soil. or for other damp locations. use UF-B wire. or use plastic conduit. UF-B wire can be difficult to strip back for wiring. Using sharp blade on utility knife, push blade into end of grey cable sheathing next to ground wire. Keep blade next to ground so it will not damage insulation on black-white wires. After cutting into sheathing 3-4,” you can gently strip grey cable sheathing from around the black and white wires, being careful not to damage insulation. Match wire size and breaker amp rating If your home was wired by professional electrician who pulled permits, then circuit breaker and wire size will match. If manufactured home or travel trailer has not been altered by homeowner then breaker and wire size will match.Safe maximumof amp draw on a breaker is 80% rated value of breaker.Look at label on each load (TV, refrigerator, box fan etc). Add up total watt load on circuit. Divide the watts by the voltage on line = amps.If breaker is oversized for wire. fire danger Breaker can let the voltage push too much amperage (current of electrons) through the matrix (atomic structure) of the wire. The natural resistance of the copper wire creates a ‘friction’ that overheats the wire and causes fire.Call electrician if you suspect wiring is not correct,Main breaker terminals are still Hot when main breaker is turned off. Absolute electrocution danger when removing cover off main panel. More information below.Use 600 volt solid copper wire only Do not use stranded wire inside main breaker box or any permanent box.Stranded wire can be used for connectors and plugs, but comes loose under screw terminals of breaker, switch, outlet, or timer etc when heat on wire causes expansion and contraction of wire.Do not use extension cord for permanent household wiring Extension cords are used for connectors and plugs only.Read about extension cord codeBuy:Southwire at AmazonResources:How to replace circuit breakerSouthwire Romex NM-B specification and usage manualSouthwire UF-B specification and usage manualAmpacities for TW and UF insulated wires: NEC table 310-16
Match breaker to voltage that shows on appliance label 240 volt: use double breaker. 120 volt: use a single breaker or tandem breaker. 3-phase breakers are used for commercial service panels. Code says: Use connected/ double-pole breakerAgainst code: Use 2 single breakers to supply 240 volt, unless the switches are connected and each rated for same ampsIf double breaker is rated for 30 amp, then BOTH sides of the breaker are each 30 amp (not 15 amp each) Power is doubled with 240 volt vs 120 volt, amps are not halvedResource:How to replace circuit breaker3-phase wiringAre both sides of 30 amp double breaker 30 amp?
Circuit breaker and wire size must match Chart on left shows that 30 amp breaker matches 10 gauge copper wire.Do not use aluminum wire. Copper wire is safe. All wire expands when electricity travels through wire. Aluminum wire expands more than copper wire. Expansion causes connection points to come loose resulting in fire hazard.Special compression fittings and CO-AL rated devices must be used with aluminum wire.Image on left shows rating for lengths up to 100′ feet for household NM-B and UF-BResources:Larger image with wire types, temperature, long lengthMaximum wattage for household NM-B and DU-F wiresWire diameter, weight, resistance
Larger image How to figure correct size wire and breaker Use chart on left to select wire and breaker (for short lengths of wire)Use the 80% rule when calculating Capacity.wattage shown on chart shows the 80% rule.When wires and breakers operate at 100%, they get warm. Warm wires mean amp loss and potential fire hazard. Warm breaker means that breaker will not last as long, and busbar can be damaged by heat (over period of time)14 ga wire ++rated for120 Voltsx 15 Amp = 1800 Watts x 80% = 1440 Watts safe maximum12 ga wire ++ rated for120 Voltsx 20 Amps = 2400 Watts x 80% = 1920 Watts safe maximum10 ga wire ++ rated for240 Voltsx 30 Amps = 7200 Watts x 80% = 5760 Watts safe maximumResourceBasic house wiring
Larger image Longer distance requires larger breaker and larger wire Look at label to find watt rating of appliance, or motor or toolmeasure distance between appliance and main breaker panelUse chart to select larger wire when neededVolts x amps = wattsWatts divided by volts = ampsVolts squared divided by watts = ohmsResources:Electrical formulas/ pdfHow to figure volts amps wattsElectric terminologyElectrical formulasWater heater formulasLarger image with wire types, temperature, long lengthMaximum wattage for household NM-B and DU-F wiresWire diameter, weight, resistance
18 gauge extension cord, used for table lamp etc is rated max 7 amps. 14 gauge extension cord, frequently used for power tool cord, is rated 10 amps.Never use extension cord in place of house wiring. House wiring is rated 600 volt, extension cords are not.Extension cords are temporary and cannot be concealed inside wall. Extension cords are made for plug ends, and have stranded wire instead of solid wire. Never put stranded wire under screw plate of switch, timer etc. or it creates fire hazard.Cords should not be warm if they are used full-timeIf you are using extension cord as full time source of electricity for pump or fan, the cord should not be warm or hot If toaster oven cord gets warm when used, then that is normalIf you operate the appliance full time, then upgrade to larger cordBuy12 gauge extension cord’Flexible cords and cables may not be used:a. As a substitute for the fixed wiring of the structure;b. Where run through holes in walls, ceilings, or floors; c. Where run through doorways, windows, or similar openings;d. Where attached to building surfaces; ore. Where concealed behind building walls, ceilings, or floors.”Flexible cord splices, repair and connections:”Flexible cords shall be used only in continuous lengths without splice or tap. No. 12 or larger, may be repaired if spliced so that the splice retains insulation, outer sheath properties, and usage characteristics.Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.” In other words, the cord must be connected or held in place by a clamp or other means so it cannot be pulled loose from terminal screws.
Circuit breaker resourcesWater heater is tripping breakerHow to replace circuit breakerHow to wire gfciCan AC breaker be used for DC breakerHow to reset circuit breakerNot enough space for circuit breakers/ use tandemCircuit breakersHow to install subpanelWhy you need ground wireSee inside breaker boxHow to wire safety switchHow to wire whole house surge protectorFigure volts amps and wattsFigure correct wire and breakerTypes of surge protection
Multimeter Test for breaks in wire/ Test for voltageMost appliance require 80% rated voltage to function correctlyBuyAnalog multimeterMultimeters at AmazonKlein multimeterElectric testers at AmazonClampmeter for testing amp flow on lineResource:How to test and replace elementHow to test thermocoupleElement tests for 120 voltsHow to test wire Safety when testing wires:Never touch wet or previously flooded appliance.Never stand on wet surface when working on electric.Never stand on bare soil, put down dry boards.Tape tester leads to wood sticks to keep hands away from power.Use non-contact voltage tester before touching wires.Never touch or lean into any made of metal.Remove metal objects from pockets.Do not use oxygen or fuel accelerants in same room as electrical repairsResource:Basic house wiring Non-contact voltage tester Test for power without touching connectorsNEVER assume power is OFFBuy:Non-contact voltage tester AmazonElectric testers at AmazonResource:How to test electric power is off
120volt15 amp devices including GFCI, timers, switches, plugs, wifi controls etc can be installed on 15 or 20 amp breaker.120 voltGFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker.Buy15 amp GFCI20 amp GFCI BuyBasic electric bookHome plumbing/ electrical codesOr learn about basic household electricity.use and search my site/ResourceSafe electric wiringBasic house wiring Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet.Buy:Klein testersOutlet testerCircuit breaker finderElectric usage monitor
Non metallic flexible cablesmust carry ground wire, but do not have hazard of short circuit causing injury from shock.Armored steel cablecan be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure.All conduit.metal, plastic. flexible and rigid. must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure.Buy:Non-metallic flexible conduitPower whipArmored cableSouthwire armored cable cutterPull boxes Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power. even when breaker is off.Buy:Electrician tools kitsKLEIN TOOLSTools kitsIRWIN toolsKNIPEX Connect wire to screw terminal Use only 600 volt solid copper wire. Do not use stranded wire or extension cord.Do not use solder anywhere on residential 120-240 volt wiring. Attach electric installation to structure. Tighten screws very tight against wire.Buy:NEC booksDewalt plumbing/ electrical codesBasic electric bookNational electric code guide/ illustratedResources:How to twist wire How to select and install twist-on wire connectors
Weatherproof lever switch on outdoor lights Safely operate outdoor toggle switchReplaces outdoor coverInstall over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etcUse weatherproof box for outdoorCan be used indoor or outdoorBuy:Best choice: Cantex lever switchOutdoor lever switches at AmazonLever switchesResourceCantex-toggle-switch-covers.pdfCantex-PVC-junction-boxes.pdf

Terminals

Buy:Crimping tool kitBlue for 16-14 wireYellow for 12-10 wireRatcheting CrimperResource:How to install terminal

Push-on wire connectors in place of twist-on connectors

Buy:Push on wire connectors AmazonRed 3P connector for 10-14 gauge wireLever connectors for stranded wire at Amazon
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.Code -Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15BuyEnd cutting nippers at Amazon When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point.Buy tools:Wire strippers at AmazonLinesman pliersPro linesman plierNeedle nose pliersEnd cutting nippers at Amazon 6″ Pull box Junction boxes for conduit and wiringBuy:Bud industries 6x6x4 best value/ no KORaco 6x6x4 metal pull boxWiegman 6x6x4 pull boxHoffman 6x6x4 pull boxAdamax raintight enclosureRaintight 6x6x4 boxPull boxesBuy:Pull boxesPolycarbonite boxesResource:Enclosures and boxes

What size wire is needed for electric water heater?

Current and wire gauge sizes that are commonly used Connect a hot water heater to a wire that is large enough to handle the heater’s current requirements. Typical hot water heater sizes are as follows: a 20-amp hot water heater requires 12-gauge wire, a 25-amp hot water heater necessitates 10-gauge wire, and a 30- to 40-amp hot water heater necessitates 8-gauge wire Electric hot water heaters normally need the installation of a dedicated 30-amp, 240-volt circuit breaker. In most cases, a 10/2 Romexcable will be used to deliver electricity from the breaker panel to your water heater (Blkwire -hot, Marked Whitewire-hot, Bare copperwire- ground).

  • A4500 watt element requires a 10/2 wire and a 30 amp (220volt) circuit breaker to be installed.
  • Furthermore, what gauge of wire do I require for a 50-gallon water heater?
  • If you’re going to run cable anyhow, simply run 10 and replace the breaker to make sure it’s done correctly the first time.
  • The majority of 50 amp water heaters will have components that are 4500 watts.

The current drawn by a 4500 volt circuit is 18.75 amps, therefore it will not trip a 20 amp breakers, but it will operate the breakers at over 95% of their 20 amp capacity rating, and most breakers are not rated for that level of operation.

What Size Breaker Does a Water Heater Need?

Circuit breakers are required for the operation of your electric water heater and gas tankless water heater. Choosing the incorrect size circuit breaker, on the other hand, might result in poor safety and even damage to the water heater. Because of the increased electrical flow via the breaker, the wires are at risk of overheating, resulting in a fire and inflicting damage to your water heater. Circuit breakers and wiring for electrical safety are specified in the National Electrical Code, which defines rules for their sizing and installation.

  • For safety reasons, it is suggested that you purchase a circuit breaker with more capacity than the electrical load of your electric devices – in this example, your water heater – to ensure that you are not electrocuted.
  • This indicates that the breaker only provides power to the water heater and does not provide power to other appliances.
  • On occasion, I’ll come upon a 4500-watt water heater that has a 20-amp circuitbreaker.
  • The size of the breaker is decided by the wattage of the heating components, not the size of the storage tank.
  • 240-volt circuit breakers are required for a water heater that has a 4500-watt heating element.
  • With a smaller 12/2 cable and a 20 amp circuit breaker, the 3800-watt heating element may be connected to the rest of the system.

Sizing Water Heater Breakers

Circuit breakers are required for the proper operation of your electric water heater and gas tankless water heater. It is possible, however, that the water heater will be damaged if the breaker is installed in the incorrect size. With the increased electrical flow through the breaker, there is a chance of the wires overheating, igniting a fire, and causing significant damage to your water heater. Circuit breakers and wiring for electrical safety are specified in the National Electrical Code, which defines criteria for their size.

  1. Therefore, it is advised that you invest in a circuit breaker of greater capacity than the electrical load of your electric appliances – in this example, a larger capacity circuit breaker than the electrical load of your water heater.
  2. In this case, the water heater is the sole thing that is powered by the breaker.
  3. A 20-amp circuitbreaker on a 4500-watt water heater is something I’ve seen once or twice in my life.
  4. Although tank size is taken into consideration, the breaker size is decided by the wattage of heating components.

In a moment, I’ll go into further detail about it. 240-volt circuit breakers are required for a water heater that has a 4500-watt heating element. A 10/2 wire is required. With a smaller 12/2 wire and a 20 amp circuit breaker, the 3800-watt heating element may be wired.

Element Watts Breaker Size 120v Breaker Size 220v Wire Gauge
1500 15 amp 15 amp 14
2000 20 amp 15 amp 14
2500 30 amp 15 amp 14
3000 30 amp 15 amp 12
3500 NA 20 amp 12
4000 NA 25 amp 10
4500 NA 30 amp 10
5000 NA 30 amp 10
5500 NA 40 amp 8

How Do You Calculate Breaker Sizing?

The power and voltage ratings of your water heater should be checked. The wattage and voltage rating of a water heater are labeled on a sticker that is attached to the thermostat panel. This information may be found around the base of certain heaters. While the majority of household water heaters have a capacity of 4500 watts or less, commercial water heaters can exceed 5500 watts or more. Let’s get down to the nitty gritty of determining the breaker sizes. 4500 divided by 240 equals 18.75 amps.

  • If you have a 4500-watt water heater that runs on 240 volts, you should be able to get 18.75 amperes out of it using the conventional division formula.
  • As a result, multiply 18.75 by 125 percent to account for the fact that a water heater operates on a continuous load.
  • When we round that value down to the next tenth, we obtain 25 amp.
  • It is commonly utilized because the minimum rating of 220 volts is greater than the 25 amp rating of the 25 amp breaker.
  • 20.45 amps multiplied by 125 percent equals 25.568 amps, which is rounded to 30 amps.
  • After all, it’s closer to 18.75 than 18.75.
  • However, according to the National Electrical Code’s 125 percent guideline, a 20 amp circuit poses a danger of frequent tripping and might cause damage to the water heater.

What Size Circuit Breaker for Gas Tankless Water Heaters?

The power and voltage specifications of your water heater should be verified. The wattage and voltage rating of a water heater are labeled on a sticker that is attached to the thermostat panel of the heater itself. This information is found around the base of certain heaters. Most household water heaters have a capacity of 4500 watts, however commercial water heaters have a maximum capacity of 5500 watts. Let’s get down to the nitty gritty of determining breaker sizes using mathematics. In this case, 4500/240 equals 18.75 amps.

  1. If you have a 4500-watt water heater that runs on 240 volts, you should be able to get 18.75 amperes out of it using the conventional division equation.
  2. To account for the fact that a water heater operates on a continuous load, multiply 18.75 by 125 percent.
  3. 25 amps is the result if we round off the number.
  4. 30 amp breakers are generally utilized since the breaker’s minimum voltage rating of 220 volts outperforms the 25 amp breaker.
  5. Even if you round up, it’s closer to 18.75.
  6. In contrast, according to the NEC 125 percent regulation, a 20 amp circuit poses a danger of frequent tripping, which might result in the water heater being permanently destroyed.

An electrical breaker of 25 amps will suffice; however, most electricians will construct a 30 amp circuit to allow for electrical fluctuations such as those described above.

Should I Have Electric Water Heater or Gas Water Heater?

This decision is based on your geographic location as well as the utility costs in your region. Gas water heaters, on the other hand, are often more expensive to purchase up front but less expensive to operate than electric water heaters. In contrast to gas water heaters, electric water heaters are more energy efficient than their gas counterparts. The cost of gas is 40 percent more than the cost of electricity. As a result, it would be more cost effective to utilize gas. Electric water heaters, on the other hand, are more cost-effective when considering the time saved over time.

If you want to make changes to your home in order to accommodate electric, gas, or tankless water heating systems, you should consult with a specialist.

Before beginning any job, you should contact with a competent expert and verify that all necessary permits have been obtained.

As an affiliate, HomeInspectionInsider.com participates in a variety of affiliate programs with other websites.

What size wire is needed for electric water heater?

To use an electric water heater, what size wire is required? A 20-amp hot water heater necessitates the use of 12-gauge wire, a 25-amp hot water heater necessitates the use of 10-gauge wire, and a 30-to-40-amp hot water heater necessitates the use of eight-gauge wire. When installing a hot water heater, can I use 10 3 wire? All you need is two insulated conductors and one ground conductor to complete the circuit. Because you have already purchased 10-3 cable, I would simply cap off the white conductor at both ends and utilize the red and black conductors for your hot wires, with the ground conductor being attached to the green screw on the water heater as a grounding point.

In order to accommodate a water heater, the usual circuit configuration is 10 conductors with ground (10/2), with a 30 amp circuit breaker for the water heater.

In order to use a 220 hot water heater, what size wire do you need?

What size wire is needed for electric water heater? – Related Questions

A 12-2 with ground should be plenty, however I would recommend a 10/2 for “upgradability” in the future.

A water heater cable with a diameter of 10/2 is the industry standard. Connect the colors white and red. Almost all water heaters would be inadequate with a 12/2 voltage.

Can I use 10-2 wire for a water heater?

A 12-2 with ground should be plenty, however I would recommend a 10/2 for “upgradability” in the event that the system becomes obsolete. For a water heater, the usual cable is 10/2. White and red are connected by a line. Almost all water heaters would be unable to operate on 12/2.

Can you use 12 2 wire for 220?

The same 12-gauge wire may be used to connect a power tool to a 220v, 20-amp outlet, saving money on wiring. If the appliance consumes 30 Amps, you’ll need a different style of receptacle as well as a thicker gauge wire.

How many amps does a 50 gallon water heater pull?

Electric water heaters with a capacity of 50 gallons consume 4500 watts on average. In a 240-volt electric circuit, 4500 watts is equal to 18.75 amps, hence 4500 watts is equal to 18.75 amps.

What size breaker do I need for a 40 gallon electric water heater?

A 40-gallon water heater should have an average capacity of 4500 Watts and an emf of 240 volts. An appropriate 25 or 30A circuit breaker is therefore sufficient for a 40-gallon circuit breaker. However, for your own safety, we recommend that you purchase a 30A circuit breaker.

What size breaker do I need for a 4500 W water heater?

For components rated at 4500 watts, a 30 Amp dual pole breaker and wire gauge of 10 gauge are required.

Do electric water heaters require 220?

Voltage requirements must be met. The majority of electric hot water heaters operate on alternating current (AC) voltages ranging from 220 to 250 volts. The hot water heaters require a double circuit breaker that is rated for the amperage draw of the hot water heaters in order to operate at this voltage in a residence.

What size wire do I need for a 240-volt heater?

A 240-volt baseboard heater necessitates the installation of a separate 20-amp or 30-amp 240-volt electrical circuit for the heater. A 20-amp circuit is capable of safely delivering 3,800 watts of power, but a 30-amp circuit is capable of delivering up to 5,700 watts of power. Circuit wire for 20-amp circuits is typically 12-gauge, whereas circuit cable for 30-amp circuits is often 10-gauge.

What wire do I use for a 30 amp breaker?

THUMB RULES AND REGULATIONS These are the rules of thumb that many techs will repeat over and over again and rely on in all situations: “Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breakers or fuses are always sized in order to protect the conductor.”

How many amps does a 60 gallon water heater use?

Electricity of 240 volts is required (a 30 amp breaker, with 10 gauge wire from the panel). Also available in a model that complies with BC regulations. Performance A 3.5-star rating is given to the 60-gallon electric water heater with a 6-year warranty.

Can you use stranded wire for water heater?

You can use Greenfield (such as BX) or liguid-tite for this purpose. Both options would be acceptable. Solid or stranded wire might be used in the installation. With only a 3K element, that must be an extremely sluggish recovery tank to operate.

What size breaker do I need for a tankless water heater?

A gas tankless water heater only requires a dedicated single-pole breaker with a 15-amp, 120-volt rating for this reason.

Does an electric water heater need to be grounded?

It should be noted that a bonding wire is not required on a water heater according to the National Electric Code (NEC).

Note that a plumbing system using PEX or other types of plastic water supply pipe does not require any type of electrical grounding to be installed in the system.

Does an electric hot water heater need a neutral?

For the time being, a neutral is not required for the typical hot water heater. In the case of 220 and 240 volt appliances with electronic controls, the neutral wires are included with the 4-wire extension cable.

Does a 240v water heater need a neutral?

It would be beneficial if it were made clear that the circuit in question was a 120/240 circuit. As long as the load is straight 240v such as a heat pump, an air conditioner compressor, or a water heater, there is no need for a neutral, and just two hots and a grounding means are required.

Will a 12 2 wire carry 30 amps?

Overloading a single 12-2 cable is not recommended. You may find it in the code book that 12 AWG wire is lawful up to 30 amps if it can be operated at 90 degrees Celsius.

What wire do I need for 220v 30-amp?

Any circuit rated for 30 amps or more must be constructed with a minimum of 10 ga copper or 8 ga aluminum. The use of larger wire sizes may be necessary for longer routes. In your situation, regardless of how far away your welder is from the breaker panel, you should utilize at least 10 copper.

Can I use 12 2 wire 230v?

If the 240v appliance requires two hot wires plus a ground, you should use the number 12/2. If you are unable to locate 12/2 wire that is black/red/ground, you can use the more common wire that is black/white/ground, in which both the black and white conduct electricity.

How many amps does a small hot water heater use?

The normal amperage for an electric water heater is 18.8 amps at 240 volts and 4500 watts, according to the manufacturer. With 115Volts, the typical use of a gas water heater is less than 12 Amps (US and Canada).

How many amps does a 80 gallon water heater pull?

This is something that should be looked at first. A water heater will only draw the amount of electricity required by the wattage of the element (s). As a result, your WH is equipped with two 4500 watt elements. When only one is in use, it consumes around 22 amps (208 is nominal voltage which is what you have in your building) 4500 divided by 208 equals 21.6 amps.

How many amps is 5500 watts at 220 volts?

As a result, 5500 watts / 220 volts X 0.80 = 20 amps is calculated.