SENSIDYNE

 

 

Sensidyne provides robust and reliable instrumentation for the detecting of toxic, combustible and oxygen gases in industrial applications. This equipment enhances safety while minimizing cost of ownership ranging from point detectors to complete plant-wide hazardous gas detection systems.

POINT GAS DETECTION | FLAME DETECTION | CONTROLLERS

 
Fixed Point Gas Detection

Point gas detectors, or gas monitors, are designed for alerting users to the presence of gas in or near a specific gas hazard. Sensidyne gas monitors are designed with a sensor head that can be mounted in a remote location - closer to a potential gas hazard - while placing the transmitter in a more convenient location, thereby simplifying maintenance. Gas monitors are relied upon by customers for personnel safety and asset protection.


Download PDF Data Sheet

SensAlert Plus

SensAlert Plus was developed with the user in mind - adding features that make it the easiest to install, use and maintain. The large, clear LCD screen& offers a non-intrusive user interface and intuitive menu structure. On 3-wire models the LCD screen is back-lit making it easy to see regardless of the location where it is installed.

  • Non-intrusive, menu driven user interface with large backlit LCD display
  • More than 50 intelligent gas detection sensors available.
  • Predictive sensor end-of-life indication displays percent sensor life remaining.
  • Remote mount sensors up to 100 feet without complicated wiring or special fixtures.
  • Test on demand gas generator for remote functionality sensor checks with real gas.
  • Universal Transmitters with automatic sensor recognition and configuration.
  • Shop calibrate sensors then field install. All calibration data will upload to the transmitter.
 


Download PDF Data Sheet

SensAlarm Plus

  • All-In-One Gas Monitor
    • Advanced Single Point Gas Detection System.
    • 1 or 2 Double-flash Strobes, Horn, and Reset.
    • Optional Battery Back-up.
  • Flexible Installation or Maintenance
    • Non-intrusive Configuration / Maintenance Interface.
    • Remote Sensor / Gassing, Duct Mount or Sample Draw.
    • Mount Sensor up to 100 Feet Away with 4 Conductor Cable.
 


Download PDF Data Sheet

Point IR Hydrocarbon

The Sensidyne Point Hydrocarbon–IR is a reliable infrared technology sensor designed to be virtually maintenance free for refineries, pipelines, drilling and production platforms, wastewater facilities and chemical plants. The unit has fast response-time and a rugged stainless steel explosion proof enclosure allowing the Point Hydrocarbon–IR to stand up to the most harsh of conditions.

  • Low Cost of Ownership.
  • High Reliability and Durability Stainless Steel Construction.
  • No Routine Calibration.
  • Virtually Maintenance Free.
  • 4-20mA & RS485 Modbus versions.
 
Flame Detection


Download PDF Data Sheet

Electro-Optical fire and flame detectors are advanced electronic devices that sense the radiated electromagnetic energy of a fire in the Ultraviolet (UV), Visible (VIS) and Infrared (IR) wavelengths and detect fires at the speed of light. Our flame detectors have extremely high false alarm immunity due to their ability to "see" using a patented WideBand™ technology that also enables them to detect both hydrocarbon and non-hydrocarbon fires using the same model. All of these fire detectors are solar blind and can be used indoors and outdoors.

  • Measures the true energy from fires.
  • Detects a fire quickly and tracks it as it grows or gets hotter.
  • Quantum type sensors respond to 0.7-3.5 micrometers on the IR spectrum.
  • Optimum false alarm immunity.
 

Controllers

Controllers provide centralized monitoring for multiple gas detection transmitters and are commonly connected to alarms, sirens, fans and can be interfaced with PLCs, DCSs and even advanced auto-dialer systems.


Download PDF Data Sheet

4-Channel Controller

The SensAlert 4-Channel Controller powers and monitors up to 4 gas detectors. With three alarm relays per channel plus a common fault relay, the Controller provides local or remote annunciation via the optional strobe and standard 90 dB buzzer. The controller has a latched alarm reset button and discrete LED value displays plus LCD displays for gas name or type and value. Discrete 4-20 mA and Modbus (RS-485) Protocol outputs are standard. Most SensAlert and SensAlert Plus transmitters, when used with this controller, will automatically configure to display the gas type, range and factory default alarms, making system set up quick and easy.

  • Visual and Audible Annunciation.
  • Discrete LED and LCD Displays.
  • Automatic Sensor Recognition.
  • 4-20 mA Analog Outputs.
  • On-Board Relays.
  • RS-485 Modbus RTU Protocol Output.
  • NEMA 4X, UL Listed Enclosure.
  • 115/230 VAC or 24 VDC.
 


Download PDF Data Sheet

16-Channel Controller

The Model 7100 16-Channel Controller provides simultaneous display and Alarm functions for 1 to 16 Analog or Modbus inputs. A graphic LCD displays monitored data as trends, bar graphs or in engineering (PPM / %LEL) units. Three adjustable alarm levels are provided per channel and relay outputs control beacons, horns and other alarm functions.

  • 1 to 16, Analog 4-20 mA or RS-485 Inputs.
  • Modbus RTU Protocol (RS-485) Output.
  • Discrete Visual Alarm Annunciation.
  • Optional Discrete Alarm Relays.
  • Multi-Mode Backlit LCD Graphic Display.
 